Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
1.
Journal of Forensic Medicine ; (6): 25-29, 2011.
Article in Chinese | WPRIM | ID: wpr-983620

ABSTRACT

OBJECTIVE@#To develop a method for simultaneous determination of sixteen antibiotics in human urine by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).@*METHODS@#With Piperacillin as an internal standard, the target antibiotics in urine samples were enriched and purified by Oasis HLB solid phase extraction (SPE) cartridges, then separated in a ZORBAX SB-C18 column with a gradient elution of mobile phase of 0.1% formic acid water and acetonitrile, finally analyzed with multiple reaction monitoring (MRM) mode.@*RESULTS@#The limits of detection (LOD) for these sixteen antibiotics were in the range of 0.05-10.0 ng/mL and the limits of quantification (LOQ) in the range of 0.25-20.0 ng/mL. Within the related linear range, the related coefficient (r) of sixteen antibiotics were all more than 0.995. Accuracies for these antibiotics were ranged from 82.0%-119.3%, the within-day precision were less than 13.9%.@*CONCLUSION@#The developed method is sensitive, specific and appropriate for the analysis of antibiotics in forensic toxicology and therapeutic drugs monitoring.


Subject(s)
Humans , Ampicillin/urine , Anti-Bacterial Agents/urine , Chromatography, High Pressure Liquid/methods , Forensic Toxicology , Hydrogen-Ion Concentration , Penicillins/urine , Reproducibility of Results , Sensitivity and Specificity , Solid Phase Extraction , Solvents/chemistry , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL